Medical Waste Incinerator NEUWI100B
$37,900.00$39,900.00 (-5%)
– High-efficiency medical waste incinerator for hospitals with 150-300 beds.
– Daily burning capacity of 50-100 kg, with 3-6 incineration cycles.
– Compact burner size: 1800mm x 1400mm x 3200mm.
– Features a 1.5m³ gasification room and 0.6m³ secondary burning room.
– Safe for infectious waste: totally enclosed operations prevent secondary pollution.
– Utilizes advanced gasification burning technology to reduce harmful emissions.
– Operating control through an automatic program to minimize manual labor.
– Compatible with both oil and gas fuel options for versatile use.
– Built-in exhaust purification system meets national environmental standards.
– Constructed to be durable with an approximate weight of 6500 kg.
Medical Waste Incinerator NEUWI100B
High-efficiency medical waste incinerator designed for mid-sized hospitals with 150–300 beds. Features advanced gasification burning technology, totally enclosed operations, and automatic program control to safely incinerate infectious waste while meeting national environmental emission standards.
Clinical overview
The NEUWI100B is a state-of-the-art medical waste incinerator engineered for mid-sized healthcare facilities. It employs advanced gasification burning technology combined with secondary combustion and exhaust purification to safely process infectious medical waste while maintaining compliance with national environmental standards. The system operates with a totally enclosed design that prevents secondary pollution and handles hazardous infectious materials with complete safety isolation.
Designed for hospitals with 150–300 beds, the incinerator processes 50–100 kg of waste per cycle across 3–6 daily incineration cycles. Its automatic program control system minimizes manual labor and operational complexity, while dual fuel compatibility (oil or gas) provides flexibility for diverse facility requirements. The robust construction (approximately 6500 kg) ensures durability and long-term reliability in demanding clinical environments.
Key features & surgeon benefits
Enclosed Operations & Emission Control
- Totally enclosed combustion chamber prevents secondary pollution
- Meets national hazardous waste burning contamination control standards
- Advanced exhaust purification system removes hydrogen chloride and sulfur oxides
- Negative pressure combustion isolates burning process from external environment
Automated Processing & High Throughput
- Automatic program control reduces operator workload and human error
- Processes 50–100 kg per cycle with 3–6 daily cycles for continuous operation
- Gasification technology eliminates melt blocks, slag lumps, and sintering issues
- Flue gas retention time exceeds 2 seconds for complete combustion of all materials
Fuel Flexibility & Operational Cost Control
- Dual fuel compatibility (oil or gas) allows selection based on facility availability and cost
- Compact footprint reduces installation space requirements
- Durable 6500 kg steel construction ensures long service life and minimal maintenance
- Efficient combustion design reduces fuel consumption and operational expenses
Multi-Material Incineration Capability
- Processes syringes, drip containers, and medical devices safely
- Handles paper-based waste, bandages, cotton wool, and general hospital refuse
- Suitable for infectious and hazardous medical waste streams
- Configurable for 220V or 380V electrical supply
Technical specifications
| Applicable Hospital Size | 150–300 beds |
|---|---|
| Burning Capacity | 50–100 kg per cycle; 3–6 cycles daily |
| Burner Dimensions | 1800 mm × 1400 mm × 3200 mm |
| Gasification Room Volume | 1.5 m³ |
| Secondary Burning Room Volume | 0.6 m³ |
| Drift/Long Burning Room Volume | 0.06 m³ |
| Filling Entrance Size | 700 mm × 900 mm |
| Chimney | Height 5 m; outer radius ø300 mm |
| Blower Power | 0.5 kW |
| Primary Combustion Machine | 0.11 kW; fuel consumption 4–10 kg/h |
| Re-burning Machine | 0.11 kW; fuel consumption 10–15 kg/h |
| Operating Voltage | 220V or 380V (selectable) |
| Fuel Type | Oil or gas (user selectable) |
| Weight | Approximately 6500 kg |
| Warranty | 2 Year Manufacturer Warranty |
Standard instrument composition
| Component | Description | Qty |
|---|---|---|
| Incinerator Unit | Complete NEUWI100B medical waste incinerator with gasification and secondary burning chambers | 1 |
| Blower Assembly | 0.5 kW air circulation blower for combustion support | 1 |
| Primary Combustion Machine | 0.11 kW fuel burner for initial gasification (4–10 kg/h consumption) | 1 |
| Re-burning Machine | 0.11 kW fuel burner for secondary combustion (10–15 kg/h consumption) | 1 |
| Exhaust Purification System | Dry purification unit with Ca(OH)₂ filtration brick for acidic gas removal | 1 |
| Chimney Assembly | 5 m height chimney with ø300 mm outer radius | 1 |
| Control System | Automatic program control panel for operation and monitoring | 1 |
| Installation Hardware | Mounting brackets, fasteners, and sealing components | As applicable |
Get in touch for pricing & availability
Contact our sales team to discuss the NEUWI100B incinerator specifications, fuel options, installation requirements, and pricing for your facility. We provide comprehensive support for system configuration, delivery, and commissioning.
Email: info@neuvar.com