Model MSLK232 Semi-automatic Cryostat Microtome, national regulated 1st class medical equipment, is a rapid pathological section instrument to human and animal body tissues. It can be widely used for pathological diagnosis, analysis and research in hospitals, medical colleges, legal medical experts and propagation institutes.

Specifications

Voltage: AC 220V±22V
Frequency:50Hz±1Hz;
Power:600W
Largest start-up current(5 second)   45A
Refrigerant:         R404a,300±10g
Compressor Type:  Double Danfoss Compressor
Compressor oil:     0.6L   EMKARATE RL-22S, ICI
Working noise:      52dB(A)

1.Section thickness range:  1-100μm Adjustable ,
1-20μm , Increment:1μm;
0-40μm, Increment:2μm;
40-100μm, Increment:5μm;

Trimming thickness range: 10-400μm Adjustable,
10-50μm , Increment:5μm;
5-100μm , Increment:10μm;
100-400μm , Increment:50μm;
Specimen retraction:  0-80μm Adjustable ,Increment:5μm
Maximum specimen size:    45mm×50mm
Horizontal stroke:     20mm
Vertical stroke:       60mm

Chamber temperature: -10℃~-40℃ Adjustable
Specimen head  temperature: -10℃~-40℃ Adjustable
3.Freezing shelf :Minimum Freezing shelf temperature:   -45℃
Number of freezing station:  26
Peltier :Minimum Peltier shelf  temperature:    -60℃
Peltier number:  2
Working time to reach -60℃:   15min

Dimension :  Size:660mm*640mm*1150mm       135kgs

Model MSLK232 Semi-automatic Cryostat Microtome, national regulated 1st class medical equipment, is a rapid pathological section instrument to human and animal body tissues. It can be widely used for pathological diagnosis, analysis and research in hospitals, medical colleges, legal medical experts and propagation institutes.

The instrument mainly consists of 4 parts:

1.The computer controlled panel is on the upper part to display the temperature and the working condition of the instrument.

2.The center part is the constant low temperature room to rapidly freeze the vivid tissue and to conduct the cutting area.

3.Behind is the mechanical transmission and motor drive.

4.The lower part is the compressor unit for cooling.

Technical Parameters
Main  specification
Voltage
 AC 220V±22V
Frequency
50Hz±1Hz;
Power
600W
Largest start-up current (5 second):
45A
Refrigerant:
R404a,300±10g
Compressor Type
Double Danfoss Compressor
Compressor oil:
0.6L EMKARATE RL-22S, ICI
Working noise
52dB(A)