Anesthesia Machine NEUGA06

$11,770.00$12,990.00 (-9%)

In stock

– High-strength engineering plastic rack for durability and corrosion resistance
– Suitable for use on adults and children
– Supports O2 and N2O gas sources with adjustable pressure (0.27~0.55MPa)
– Multiple flow meter options for precise gas delivery (O2 and N2O)
– Automatic vaporizer compensation based on pressure, temperature, and flow rate
– High-definition 5.7” LCD display for clear monitoring
– Versatile ventilation modes including IPPV, SIPPV, SIMV, PEEP, and MANUAL
– Comprehensive monitoring of ventilation parameters and oxygen concentration (21%~100%)
– State-of-the-art security alarm system for various safety metrics
– Operates on standard AC power (220V±10%) with UPS and storage battery options

SKU: NEUGA06 Category: Brand:

Main bodyHigh-strength engineering plastic rack, light,

beautiful and corrosion resistant

Scope of applicationadult, child
Gas sourceO2: 0.27~0.55MPa    N2O: 0.27~0.55MPa
Flow meter 

O2 : 0.1~1.0L/min   1.1~10L/min

N20: 0.1~1.0L/min     1.1~10L/min
O2, N2O linkage and N2O Stopper

When using nitrous oxide, oxygen concentration>25%;

When the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off.

Flow rate of rapid oxygen supply25~75L/min
Low oxygen pressure alarm (Oxygen Alarm)There will be sound alarm when the oxygen

pressure < 0.2MPa

Vaporizer (Vaporizer Definition and Vaporizer Construction)it has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5 vol%. Among Halothane,Enflurane, Isoflurane and Sevoflurane, two can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available.
Respiratory circuitworking mode: all-close, semi-close, semi-open

APL: 0.5~7 kPa

Respiratory Bellows bellows for adults, tidal volume range:0~1500 ml

bellows for children, tidal volume range:0~300 ml

anyone can be chosen for application as

required by the customer

Ventilator (Ventilator Definition and Ventilator Function)
Display modehigh-definition 5.7” LCD display
Ventilation modeIPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH
Ventilation parametersTidal volume20~1500 ml
Rate1~99 bpm
SIMV rate2~20 bpm
I:E4:1~1:8
Inspiratory trigger pressure-1.0~2.0 kPa
PEEP0~2.0 kPa
Pressure range1.0~6.0 kPa
SIGH1.5 times the inspiratory time

(70-150 adjustable)

 

Parameters for ventilation monitoringtidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, average pressure, pressure – time waveform, flow rate – time waveform,PEEP,inspiratory trigger pressure, Inspiratory platform, autonomous inspiratory rate, lung compliance, airway resistance, flow-volume loop, pressure-volume loop
Monitoring of oxygen concentration(21%~100%)
Security Alarm System
Oxygen Concentration alarmupper limit setting range  21%~100%

low limit setting range    10%~80%

Airway pressure alarmupper limit setting range  0.3~6.0 kPa

low limit setting range     0.2~5.0 kPa

Per-minute ventilation volume alarmupper limit setting range   3.0~30L/min

low limit setting range    1.0~10L/min

Sustained high-pressure alarmit will give alarm when stress have consistently been higher than 2.5 kPa
Suffocation alarmit will give sound and light alarm if there is no tidal volume input for 15 seconds
Power alarm
PowerAC 220V±10%     50Hz±1Hz(UPS, Storage battery)