ATP Meter with Swabs Hygiene Monitor Device ATP Tester Machine Bacteria Detector NEUATP01
$1,790.00$1,990.00 (-10%)
– High sensitivity for detecting microorganism levels (10-15 to 10-18 mol).
– Fast testing time of just 15 seconds compared to traditional methods (18-24 hours).
– User-friendly design allows for easy operation with minimal training.
– Features a 3.5-inch high-precision graphic touch screen for clear display.
– Detection range up to 9999 RLUs with automatic pass/fail judgment.
– Equipped with rechargeable lithium battery for long-lasting use.
– Supports 50 user ID settings and customizable result limits (up to 251).
– Self-calibration and built-in light source for consistent accuracy.
– Comes with mini USB interface for easy data upload to PC.
– Integrated wet collection swab for efficient sample collection.
– Compact size (188 mm x 77 mm x 37 mm) for portability and convenience.
Specifications
Atp tester machine NEUATP01 characteristics:
Practicability —— The upper and lower limits can be set according to the requirements of environmental testing, so that data can be quickly evaluated and warned, and surface cleanliness can be quickly screened. High sensitivity-10-15 ~ 10-18 mol Fast speed-the conventional cultivation method is more than 18-24h, while ATP only needs more than ten seconds. Feasibility-The number of microorganisms has a clear correlation with the ATP contained in the microorganisms. By detecting the ATP content, the number of microorganisms in the reaction can be indirectly obtained Maneuverability-Traditional training methods need to be operated by trained technicians in the laboratory; and ATP rapid cleanliness testing is very simple to operate, and only simple training can be performed by ordinary staff on site. Better experience —— The test tube adopts a plug-in flexible design, which can be cleaned regularly for long-term use and extend the life of the instrument.
Monitor device ATP tester machine NEUATP01 main parameters:
1. Display: 3.5-inch high-precision graphic touch screen
2. Processor: 32-bit high-speed data processing chip
3. Detection accuracy: 1 × 10-18mol
4. Coliform group: 1-106cfu
5. Detection range: 0 to 9999 RLUs
6. Detection time: 15 seconds
7. Detection interference: ± 5 ﹪ or ± 5 RLUs
8. Operating temperature range: 5 ℃ to 40 ℃
9. Operating humidity range: 20-85 ﹪
10. ATP recovery rate: 90-110%
11. Detection mode: RLU, coliform screening
12. 50 user ID settings
13. The number of result limits that can be set: 251
14. Automatically judge pass and fail
15. Automatic statistical pass rate
16. Built-in self-calibration light source
17. 30 seconds self-test after booting
18. Equipped with mini USB interface, you can upload the results to PC
19. Equipped with special software driver U disk instead of traditional CD
20. Instrument size (W × H × D): 188 mm × 77mm × 37mm
21. Use rechargeable lithium battery to avoid battery replacement
22. Standby state (20 ℃): 6 months
23. Stable liquid luciferase
24. Wet integrated collection swab