Semi-auto Chemistry Analyzer RT-9000
$3,190.00$3,950.00 (-19%)
– User-friendly Windows operating system with built-in mouse and large color LCD
– Versatile reagent system supporting flow cell and cuvette modes
– Multiple analytical modes including kinetic and fixed time
– Real-time curve monitoring for enhanced test result reliability
– Large memory for up to 200 test protocols and 3000 test results
– Comprehensive QC functions including Westguard Multi-rule and Levey Jennings plot
– Auto power on self-check for convenient operation
– Compact design allows for easy user maintenance
– Multi-language software and customizable OEM options available
– Various result output formats including patient comprehensive reports
Semi-auto Chemistry Analyzer RT-9000
Advanced Semi-Automated Clinical Chemistry Analysis System
The RT-9000 combines user-friendly Windows operation with versatile analytical capabilities, offering real-time curve monitoring, comprehensive QC functions, and a compact design perfect for laboratories seeking reliable and efficient chemistry analysis.
ISO Certified
Clinical Grade
24/7 Support
Quality Assured
Introduction to the Semi-auto Chemistry Analyzer RT-9000
The Semi-auto Chemistry Analyzer RT-9000 represents a breakthrough in clinical chemistry analysis, combining advanced technology with user-friendly operation. Designed for modern laboratories that demand precision, reliability, and efficiency, the RT-9000 offers a comprehensive solution for routine and specialized chemistry testing. Its Windows-based operating system with intuitive mouse control and large color LCD display ensures ease of use for laboratory professionals of all experience levels.
Featuring an open reagent system that supports both flow cell and cuvette modes, the RT-9000 provides exceptional flexibility in test methodology. With multiple analytical modes including kinetic, fixed time, and bichromatic end point analysis, this analyzer can accommodate a wide range of clinical chemistry assays. The real-time curve monitoring feature enhances result reliability by allowing immediate visualization of reaction kinetics, while the powerful QC functions including Westguard Multi-rule and Levey Jennings plots ensure consistent quality control. The compact design with user-serviceable components makes maintenance straightforward, reducing downtime and operational costs.
Clinical Applications
Technical Specifications
| Model | RT-9000 |
| SKU | RT-9000 |
| Photometric Range | -0.500~3.500 Abs |
| Resolution | 0.001 Abs (displayed), 0.0001 Abs (calculated) |
| Light Source | Halogen lamp |
| Wavelengths | 340, 405, 500, 546, 578, 620, 670 nm, 1 more filter optional |
| Band Width | ≤10 nm |
| Aspirate Volume | 400 μL ~ 3000 μL |
| Memory Capacity | Around 200 test protocols and up to 3000 test results |
| Interface | RS-232, USB, SD card interface |
| Measurement Mode | Metal-quartz flow cell and cuvette optional |
| Temperature Control | 25°C, 30°C, 37°C; ±0.5°C |
| Display | Large color LCD |
| Input | USB mouse, built-in keyboard or external USB keyboard |
| Output | Built-in printer or external printer (optional) |
| Power Supply | AC 110V/220V ±10%, 50Hz/60Hz |
| Net Weight | 8 kg |
| Dimensions (L × W × H) | 350 × 330 × 165 mm |
Key Features and Benefits
User-Friendly Windows Operation
Intuitive Windows-based operating system with mouse control and built-in keyboard provides easy navigation and operation. The large color LCD display ensures clear visualization of test parameters, results, and real-time reaction curves, making the analyzer accessible to operators of all skill levels.
Open Reagent System
Flexible reagent system supports both flow cell and cuvette modes, allowing laboratories to choose from a wide range of reagents and methodologies. The open system design reduces reagent costs and provides freedom in test menu customization, with closed system options available upon request.
Multiple Analytical Modes
Comprehensive analytical capabilities include kinetic, fixed time, and bichromatic end point methods with or without reagent blank or sample blank. Linear and non-linear calibration options ensure accurate results across a wide range of analyte concentrations and test methodologies.
Real-Time Curve Monitoring
Advanced real-time curve monitoring feature displays reaction kinetics as they occur, enhancing the reliability and validity of test results. Operators can immediately identify reaction abnormalities, substrate depletion, or interference, ensuring only accurate results are reported.
Large Memory Capacity
Extensive memory stores up to 200 programmable test protocols and 3000 test results, eliminating the need for frequent data downloads and enabling comprehensive historical record keeping. This capacity supports high-volume laboratories and facilitates long-term quality control tracking.
Powerful QC Functions
Sophisticated quality control features include Westguard Multi-rule analysis and Levey Jennings plots with support for two controls per test. These comprehensive QC tools ensure consistent performance monitoring and immediate detection of analytical problems, maintaining the highest standards of result accuracy.
Auto Power-On Self-Check
Automated self-check sequence upon power-on verifies all system components and functions are operating correctly before testing begins. This feature ensures system readiness and helps identify potential issues before they affect test results, enhancing reliability and reducing troubleshooting time.
Lamp Saving Technology
Intelligent lamp saving and wake-up function extends the lifespan of the halogen light source by automatically dimming during idle periods and quickly restoring full intensity when testing resumes. This feature reduces operational costs and minimizes the frequency of lamp replacements.
Multiple Result Output Formats
Versatile result output options include comprehensive patient reports with historical data, individual test results, and batch summaries. Results can be printed using built-in or external printers, exported via USB or SD card, or transmitted through RS-232 interface for laboratory information system integration.
User-Serviceable Design
Compact design with modular components enables laboratory staff to perform routine maintenance tasks without requiring specialized service personnel. This DIY maintenance capability reduces downtime, lowers service costs, and ensures the analyzer remains operational when needed most.
Multi-Language Support
Software available in multiple languages accommodates diverse user populations and international laboratory settings. The multi-language capability ensures operators can work in their preferred language, reducing training time and minimizing operational errors.
Customizable OEM Options
Flexible OEM customization options allow laboratories and distributors to tailor the RT-9000 to specific market requirements. Custom branding, specialized test protocols, and region-specific configurations are available to meet diverse operational needs and regulatory requirements.
Why Choose the Semi-auto Chemistry Analyzer RT-9000
Unmatched Versatility and Flexibility: The RT-9000 stands out in the semi-automated chemistry analyzer market through its exceptional versatility. The open reagent system with dual flow cell and cuvette capability provides laboratories with unprecedented flexibility in test menu selection and methodology. Whether running high-volume routine chemistry or specialized low-volume assays, the RT-9000 adapts to your laboratory’s unique needs. The multiple analytical modes support virtually any chemistry assay, from simple endpoint determinations to complex kinetic enzyme measurements, making it a truly universal chemistry platform.
Superior Quality Control and Result Reliability: Quality control is paramount in clinical chemistry, and the RT-9000 delivers industry-leading QC capabilities. The implementation of Westguard Multi-rule analysis provides sophisticated statistical process control that detects systematic and random errors before they affect patient results. Combined with Levey Jennings plotting for visual trend analysis and support for two control levels per test, the RT-9000 ensures your laboratory maintains the highest standards of analytical quality. Real-time curve monitoring adds an additional layer of result verification by allowing immediate visual inspection of reaction kinetics, catching problems that traditional endpoint analyzers might miss.
Operational Efficiency and Cost-Effectiveness: The RT-9000 is designed to maximize laboratory efficiency while minimizing operational costs. The large memory capacity reduces administrative burden by storing extensive test protocols and patient results, while the automated self-check feature ensures system readiness without manual intervention. The lamp saving technology significantly extends light source life, reducing replacement costs and maintenance downtime. The compact, user-serviceable design means your laboratory staff can handle routine maintenance tasks, eliminating expensive service calls and minimizing instrument downtime. The open reagent system provides freedom to select cost-effective reagents without being locked into proprietary consumables.
Future-Proof Technology with Comprehensive Support: Investing in the RT-9000 means investing in technology that will serve your laboratory for years to come. The Windows-based operating system provides a familiar interface that reduces training time and ensures compatibility with evolving IT infrastructure. Multiple connectivity options including RS-232, USB, and SD card interface enable seamless integration with laboratory information systems and support various data management workflows. The multi-language software and customizable OEM options ensure the RT-9000 can be adapted to changing laboratory needs and expanding service areas. With comprehensive technical support and a global service network, Neuvar Inc. stands behind the RT-9000 with the resources and expertise to keep your analyzer performing at peak efficiency throughout its operational life.
Frequently Asked Questions
What types of assays can the RT-9000 perform?
The RT-9000 supports a comprehensive range of clinical chemistry assays including kinetic enzyme measurements, fixed time endpoint assays, and bichromatic endpoint determinations. It can perform routine chemistry tests such as glucose, cholesterol, triglycerides, liver enzymes, kidney function markers, electrolytes, and specialized tests including therapeutic drug monitoring and enzyme kinetics. The open reagent system and multiple analytical modes provide flexibility to run virtually any photometric chemistry assay within the instrument’s wavelength and absorbance range.
How does the open reagent system benefit my laboratory?
The open reagent system provides significant advantages including freedom to choose from multiple reagent suppliers, reducing costs through competitive pricing and eliminating vendor lock-in. You can select reagents based on performance, cost, or availability without being restricted to proprietary consumables. The system supports both flow cell and cuvette modes, accommodating different reagent formats and methodologies. This flexibility enables test menu customization to meet your specific patient population needs and allows you to add new tests as your laboratory services expand.
What quality control features does the RT-9000 offer?
The RT-9000 includes comprehensive quality control capabilities with Westguard Multi-rule analysis for sophisticated statistical process control, Levey Jennings plotting for visual trend analysis, and support for two control levels per test. Real-time curve monitoring allows immediate visualization of reaction kinetics to detect analytical problems. The system stores extensive QC data for compliance documentation and performance trending. These features work together to ensure result accuracy and reliability while meeting regulatory requirements for clinical laboratory quality assurance.
How easy is the RT-9000 to operate and maintain?
The RT-9000 is designed for user-friendly operation with a Windows-based interface, mouse control, and large color LCD display that requires minimal training. The auto power-on self-check verifies system readiness automatically. The compact, modular design enables laboratory staff to perform routine maintenance tasks such as lamp replacement, flow cell cleaning, and component inspection without specialized service personnel. Comprehensive on-screen help and multi-language support further simplify operation. This DIY maintenance capability reduces downtime and service costs significantly.
What is the throughput capacity of the RT-9000?
As a semi-automated analyzer, the RT-9000’s throughput depends on the specific test methodology and operator efficiency. For typical endpoint assays, experienced operators can process 60-120 tests per hour depending on the test protocol and number of different assays being run. Kinetic assays require longer measurement times and will have correspondingly lower throughput. The large memory storing 200 test protocols and 3000 results supports high-volume operations without frequent data downloads. The efficient workflow design and real-time monitoring optimize productivity for semi-automated operations.
Can the RT-9000 integrate with our laboratory information system?
Yes, the RT-9000 offers multiple connectivity options for laboratory information system integration. The RS-232 interface supports bidirectional communication with most LIS systems using standard protocols. USB connectivity enables data transfer to computers for further processing or storage. The SD card interface provides an alternative method for data export and backup. Results can be output in various formats including patient comprehensive reports, batch summaries, and individual test results. This flexibility ensures the RT-9000 can integrate into existing laboratory workflows and information management systems.
What wavelengths are available and can they be customized?
The RT-9000 comes standard with seven wavelengths: 340, 405, 500, 546, 578, 620, and 670 nm, covering the most commonly used wavelengths in clinical chemistry. An eighth wavelength filter can be optionally installed to accommodate specialized assays. The bandwidth is ≤10 nm, providing excellent specificity for photometric measurements. This wavelength selection supports the vast majority of clinical chemistry assays including enzyme kinetics, substrate measurements, and specialized colorimetric tests. The optional additional filter can be specified at time of purchase to meet specific laboratory requirements.
What training and support does Neuvar provide for the RT-9000?
Neuvar Inc. provides comprehensive training and support for the RT-9000 including detailed operation manuals, on-site installation training, and ongoing technical support. The intuitive Windows-based interface and multi-language software minimize training requirements. Technical support is available to assist with protocol programming, troubleshooting, and optimization. The user-serviceable design is supported by maintenance training materials enabling laboratory staff to perform routine service tasks. Application support helps laboratories implement new test protocols and optimize existing assays. Neuvar’s commitment to customer success ensures your RT-9000 investment delivers maximum value throughout its operational life.
Contact Us